Status LED
Out
1
ATTN
2
Fault-Service Required/
Locate LED
3
DPCC OK indicator

AC Power Block Inlet Indicators

Each power inlet on the AC power block at the server back panel has a single green OK
indicator that turns steady on only when the power at the connector is sufficient for the power
supply unit. The following figure shows AC inlets 0-3.
The server back panel AC inlets have the following designations.
Icon and
Description
Color
ATTN
Attention (ATTN) DPCC recessed pinhole button to initiate DPCC removal and install
Indicates a fault state in DPCC:
■ Off – Server is operating normally.
■ Steady On – A fault is present in chassis SMOD0 System A.
Amber
DPCC Locate LED:
■ Off – DPCC is operating normally.
■ Fast blink – Use Oracle ILOM to activate this LED to enable you to locate a DPCC
quickly and easily.
Indicates the operational state of DPCC:
■ Off – DPCC power is not present.
■ Flashing – DPCC is booting.
■ Steady On – DPCC power is on and running.