Identify and Remove a Faulty DIMM
If the DIMM Fault LED is off, then the DIMM is operating properly.
If the DIMM Fault LED is on (amber), then the DIMM is faulty and should be replaced [4].
To locate the failed DIMM, press and hold the Fault Remind button [1].
This procedure uses the DIMM fault remind test circuit in the CMOD to identify the failed
DIMM. The circuit is a charged, time-limited circuit. Once power is removed from the server
you have 10 minutes to use the circuit for troubleshooting.
Call Out
1
2
3
4
5
6
Verify that the green Fault Remind Power LED indicator [1] is lit.
6.
The Charge Status indicator [2] lights if the Fault Remind circuit is operational.
The Fault Remind circuit remains charged for about 10 minutes after power is removed from
the CMOD, either by disconnecting power from the server, or by removing the CMOD from the
chassis. When you press the Fault Remind button, the Charge Status indicator lights if there is
enough power to use the fault remind circuit. Otherwise it remains unlit.
190
Oracle Server X7-8 Service Manual • April 2018
Description
Fault Remind button. To locate a failed DIMM, press and hold.
Fault Remind Power LED Charge Status indicator
DIMM slots
DIMM slot fault LED indicators (one for each slot)
Processor
Processor fault LED indicator