Troubleshooting Using Status Indicators
PS Fault
For a server with a power supply (PS) in a fault state, the server amber Fault-Service Required
LEDs (front and back) and the amber Fault-Service Required indicator on the PS0-3 are steady
on. The front and back green On/Standby, System OK, and the green SP indicators are steady
on.
Memory Fault
For a server with a fault in the memory subsystem, the server amber Fault-Service Required
LEDs (front and back) and an amber CMOD Fault-Service Required LED are steady on. The
front and back green On/Standby, System OK, and the green SP indicators are steady on.
CPU Fault
For a server with a fault in the processor subsystem, the server amber Fault-Service Required
LEDs (front and back) and an amber CMOD Fault-Service Required LED are steady on. The
activity of front and back green On/Standby, System OK, and the green SP indicators vary
depending on whether the server can boot successfully. The server might not be able to boot out
of Standby power mode.
Fan Module Fault
For a server with a fan module fault, the server amber Fault-Service Required LEDs (front and
back) and an amber Fault-Service Required LED on a fan module are steady on. The front and
back green On/Standby, System OK indicator, and the green SP indicators are steady on.
Service Processor Fault
For a server with an SP (service processor) fault, the server amber Fault-Service Required
LEDs (front and back) are steady on. The front and back System OK indicators and the SP OK
indicator are off.