Oracle X7-8 Service Manual page 197

Hide thumbs Also See for X7-8:
Table of Contents

Advertisement

Ensure that that all DIMM levers are in the fully upright and locked position.
c.
Ensure that the processor configuration matches the installed CMODs.
For processor configuration information, see
Ensure that the DIMM configuration matches the installed CMODs.
d.
For DIMM configuration information, see
e.
Replace the CMOD cover.
Lower the cover onto the CMOD. To install the CMOD cover, align the standoffs on the
inside of the cover with the slots in the CMOD chassis. This position leaves a gap between
the lead edge of the cover and the front edge of the CMOD.
Slide the cover toward the front of the CMOD until it locks in place.
See
"Install the CMOD Cover" on page
5.
To upgrade the server, do the following:
a.
Install a CMOD in the first vacant slot at the farthest left position.
See
"Install a CMOD" on page
b.
Repeat the above step for the remaining three slots.
6.
Install both fan frames.
See
"Install a Fan Frame" on page
7.
Install all eight fan modules.
See
"Install a Fan Module" on page
Prepare the server for operation.
8.
See
"Returning the Server to Operation" on page
9.
Configure the new CMODs.
See
"Configuring the System Socket Modes" on page
Upgrade the Server From Four to Eight CMODs (FRU)
"Product Description" on page
"DIMM Population Rules" on page
166.
167.
137.
133.
245.
247.
15.
184.
Servicing Components
197