Oracle X7-8 Service Manual page 50

Hide thumbs Also See for X7-8:
Table of Contents

Advertisement

Identify Hardware Faults (Oracle ILOM)
The subsystem information page appears.
The above example shows the Memory subsystem screen and indicates that DIMM 8 on CPU 0
has an uncorrectable ECC fault.
To get more information, click one of the Open Problems links.
5.
The Open Problems screen provides detailed information, such as the time the event occurred,
the component and subsystem name, and a description of the issue. It also includes a link to a
KnowledgeBase article.
The System Log provides a chronological list of all the system events and faults that have
Tip -
occurred since the log was last reset and includes additional information, such as severity levels
and error counts. To access it, click the System Log link.
In this example, the hardware fault with DIMM 8 of CPU 0 requires local (physical) access to
the server.
Before going to the server, review the
6.
information related to the issue or the component.
For up-to-date information about the server, including hardware-related issues, refer to Oracle
Server X7-8 Product Notes at:
7.
To prepare the server for service, see
50
Oracle Server X7-8 Service Manual • April 2018
Oracle Server X7-8 Product Notes
https://www.oracle.com/goto/x7-8/docs
"Preparing for Service" on page
for
97.

Advertisement

Table of Contents
loading

Table of Contents