Remove a Fan Module
Call
Out
2
3
3.
To unlock the fan module, push in the green release button.
Caution -
system is in Main power mode. This action removes power from the CMODs and causes an
immediate shutdown. On an eight-CMOD system, this applies to all fan modules. On a four-
CMOD system, this applies to the fan modules in the left-side fan frame.
4.
To remove the fan module, pull it out of the slot.
Caution -
into the vacant fan module slot with your hand or any object. Do not touch the exposed CMOD
fan module power connector.
When the fan is removed from the slot, a hinged air vane drops down to close the slot. The vane
maintains system cooling and prevents a disruption of server airflow during hot service.
132
Oracle Server X7-8 Service Manual • April 2018
Status LED or Button
OK
Release button
Data Loss. Do not remove more than one fan module from a column while the
Electrical hazard. During a hot-service procedure, voltage is present. Do not reach
Icon
Description
and
Color
Indicates the functional state of the fan module:
■ Steady On – Fan module is powered on and
functioning normally.
■ Off – Fan module is powered off and not functioning.
Green
None
Press the green button to release and remove the fan
module.