Corona; Corona Wire Replacement - Ricoh FT4430 Service Manual

Table of Contents

Advertisement

CORONA

1. Corona Wire Replacement

- Do not handle new corona wires with your bare hands. Oil on the
wire will cause uneven charge on the drum.
- Do not rub the corona wires with rough material (sandpaper, etc.) as
it will damage the corona wires.
- When removing the endblock covers, be careful not to break off the
side hooks.
- Do not use any solvents to clean the wire as it will cause uneven
charge on the drum.
o
- Charge Corona Wire -
1. Slide the wire cleaner [A] away from the front endblock [B] as shown.
2. Remove the front [C] and rear [D] end block covers.
3. Slide the wire cleaner back to the front end and remove it.
5-57