7. Cleaning Pressure Adjustment

[ A ]
ADJUSTMENT STANDARD: A =
1. Turn off the main switch.
2. Remove the rear cover (2 screws).
3.
Disconnect the fiber cables from the interface board if the DF is installed.
4. Lower the main PCB (2 screws).
5. isconnect the AC harness from the T&S power pack and remove it (1
screw).
6.
Lightly secure the cleaning solenoid [A] at the center of the bracket [B].
7. Position the cleaning solenoid to measuring the gap "A", then secure the
cleaning solenoid.
NOTE: When adjusting the gap "A", make sure that the solenoid plunger is
all the way to the right.
[ A']
5-33
16 April '88