16 April '88
[
4. Unhook the corona wire [A] from the front anchor post [B] by pulling in
the direction of the arrow using a small screw driver.
5. Remove the old corona wire.
6. Clean the endblocks, the covers,
blower brush and dry cloth.
7. Hook the new corona wire onto the
8. ,Hook the other end of the wire onto the front anchor post using a small
screw driver.
When installing the corona wire, the wire junction [D] should be
positioned inside the rear endblock.
9. Reassemble the charge corona unit. Make sure that the corona wire is
positioned between the cleaner pads [E].
and the corona
tension spring [c]
5-58
unit casing with a
\

Advertisement