Ricoh FT4430 Service Manual page 163

Table of Contents

Advertisement

16 April '88
2nd Scanner Hight Adjustment
13.
ADJUSTMENT
STANDARD
NOTE: It is
required to adjust
images appears on a copy.
1. Turn off the main switch.
2. Remove the exposure glass. (See Exposure Glass Removal.)
3. Loosen the alIen screw on the excentric can [A] using a allen screw key.
4. Adjust the bight by turning the xcentric cam.
Clock wise:
Counterclockwise:
45 d e g r e e
:
the 2nd Scanner height when non square
The height is decreased.
The height is increased.
5-16