16 April '88
7
Hook the tension spring onto the other end of the corona wire. Then
hook the tension spring onto the front endblock anchor post.
Insert the wire junction [A] of the new separation corona wire through the
8 .
hole in the rear endblock and hook the terminal spring onto the nearby
wire junction.
9
Hook the tension spring onto the other end of the loop and then hook
the spring to the front endblock anchor post.
The separation corona wire should be properly positioned in the
grooves of the front and rear endblocks.
10. Reset the endblock covers anti the corona paper guide