16
April '88
7. Remove the front stud screw [A] and take out the original entrance guide
[B] .
Unhook the spring [C] of the misfeed prevention lever [D] and remove
8.
the misfeed prevention lever and the bushing [E] (1 E-ring [F]).
9. Remove the wear prevention lever [G] (1 E-ring) and the bushings on the
friction roller shaft [H].