Alarms, faults and system messages

8.6 List of alarms and faults

8.6
List of alarms and faults
Axxxxx Alarm
Fyyyyy: Fault
Table 8-7
The most important alarms and faults
Number
Cause
F01000
Software fault in CU
F01001
Floating-point exception
F01015
Software fault in CU
F01018
Power-up aborted more than once
A01028
Configuration error
F01033
Switching over units: Reference pa‐
rameter value invalid
F01034
Switching over units: Calculation of
the parameter values after refer‐
ence value change unsuccessful
F01040
Parameters must be saved
F01044
Loading memory data card defec‐
tive
A01053
System overload measured
F01054
System limit exceeded
F01105
CU: Insufficient memory
F01122
Frequency at the probe input too
high
F01205
CU: Time slice overflow
F01250
CU hardware fault
F01512
An attempt has been made to es‐
tablish a conversion factor for scal‐
ing which does not exist
A01590
Motor maintenance interval elapsed Carry out maintenance and reset the maintenance interval (p0651).
F01600
STOP A triggered
386
Remedy
Replacing the Control Unit.
Switch the Control Unit off and on again.
Upgrade firmware or contact technical support.
1. Switch the module off and on again.
2. After this fault has been output, the module is booted with the factory
settings.
3. Recommission the inverter.
Explanation: Parameterization on the memory card has been created with
a different type of module (Article number, MLFB).
Check the module parameters and recommission if necessary.
Set the value of the reference parameter not equal to 0.0 (p0304, p0305,
p0310, p0596, p2000, p2001, p2002, p2003, r2004).
Select the value of the reference parameter so that the parameters involved
can be calculated in the per unit notation (p0304, p0305, p0310, p0596,
p2000, p2001, p2002, p2003, r2004).
Save parameters (p0971).
Switch the Control Unit off and on again.
Replace the memory card or the Control Unit.
The maximum computing power of the Control Unit was exceeded. The
following measures reduce the load on the Control Unit:
● Use only one data record (CDS and DDS)
● Only use the safety features of the basic functions
● Deactivate the technology controller
● Use the simple ramp-function generator rather than the extended ramp-
function generator
● Do not use any free function blocks
● Reduce the sampling time of the free function blocks
Reduce number of data sets.
Reduce the frequency of the pulses at the probe input.
Contact technical support.
Replacing the Control Unit.
Create scaling or check transfer value.
Select the STO safety function and then deselect again.