Siemens SINAMICS G120 Operating Instructions Manual page 66

Low voltage converters chassis devices with cu240b-2 and cu240e-2
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Installing
4.3 Installing Power Modules
Table 4-12
Frame
size
FSA
FSB
FSC
The Power Modules are designed for mounting without any lateral cooling air clearance. For tolerance
1)
reasons, we recommend a lateral clearance of 1 mm.
66
Drilling dimensions, cooling clearances and fixing
Control cabinet cutout [mm]
a
b
c
d
103
106
27
198
148
134
34.5
304
123
174
30.5
365
Cooling air clearances
[mm]
1)
e
Top
Bottom
88
80
100
116
80
100
156
80
100
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2017, FW V4.7 SP6, A5E34259001B AD
Fixing/torque
Front
100
8 x M5 / 3.5 Nm
100
8 x M5 / 3.5 Nm
100
10 x M5 / 3.5 Nm

Advertisement

Table of Contents
loading