Table 10-15 PM240-2, PT, Frame Size B, 3-ph. AC 380 V ... 480 V
Article no. without filter
Article no. with filter
LO base load output
LO base load input current
LO base load output current
HO base load output
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss
Required cooling air flow
Weight without filter
Weight with filter
1) approx. 0.16 kW through the heatsink
Table 10-16 PM240-2, IP20, Frame Size C, 3-ph. AC 380 V ... 480 V
Article no. without filter
Article no. with filter
LO base load output
LO base load input current
LO base load output current
HO base load output
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss
Required cooling air flow
Weight without filter
Weight with filter
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2017, FW V4.7 SP6, A5E34259001B AD
6SL3211-1PE21-8UL0
6SL3211-1PE21-8AL0
7.5 kW
22.2 A
18.0 A
5.5 kW
19.8 A
13.7 A
3NA3812 (32 A)
35 A
0.2 kW
1)
9.2 l/s
3.6 kg
3.9 kg
6SL3210-1PE22-7UL0
6SL3210-1PE22-7AL0
11.0 kW
32.6 A
26.0 A
7.5 kW
27.0 A
18.0 A
3NA3820 (50 A)
50 A
0.3 kW
18.5 l/s
4.7 kg
5.3 kg
10.4 Technical data, PM240-2 Power Module
6SL3210-1PE23-3UL0
6SL3210-1PE23-3AL0
15.0 kW
39.9 A
32.0 A
11.0 kW
36.0 A
26.0 A
3NA3820 (50 A)
50 A
0.37 kW
18.5 l/s
4.8 kg
5.4 kg