Siemens SINAMICS G120 Operating Instructions Manual page 381

Low voltage converters chassis devices with cu240b-2 and cu240e-2
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Parameter
r2123
r2124
r2125
r2145
r2132
r2134
r2146
Extended settings for alarms
Parameter
You can change up to 20 different alarms into a fault or suppress alarms:
p2118
p2119
You will find details in function diagram 8075 and in the parameter description of the List
Manual.
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2017, FW V4.7 SP6, A5E34259001B AD
Description
Alarm time received in milliseconds
Displays the time in milliseconds when the alarm occurred
Alarm value
Displays additional information about the alarm
Alarm time removed in milliseconds
Displays the time in milliseconds when the alarm was removed
Alarm time received in days
Displays the time in days when the alarm occurred
Actual alarm code
Displays the code of the alarm that last occurred
Alarm value for float values
Displays additional information about the alarm that occurred for float values
Alarm time removed in days
Displays the time in days when the alarm was removed
Description
Setting the message number for the message type
Selection of the alarms for which the message type should be changed
Setting the message type
Setting the message type for the selected alarm
1: Fault
2: Alarm
3: No message
Alarms, faults and system messages
8.4 Alarms, alarm buffer, and alarm history