Advanced commissioning
6.5 Drive control via PROFIBUS or PROFINET
No.
C9 hex
CC hex
PNU (parameter number) and page index
The parameter number is located in value PNU in the 1st word of the parameter channel (PKE).
The page index is located in the 2nd word of the parameter channel (IND bit 7 ... 0).
Parameter number
0000 ... 1999
2000 ... 3999
6000 ... 7999
8000 ... 9999
10000 ... 11999
20000 ... 21999
30000 ... 31999
60000 ... 61999
Subindex
For indexed parameters, the parameter index is located in subindex (IND Bit 15 ... 8) as
hexadecimal value.
PWE: Parameter value or connector
Parameter values or connectors can be located in the PWE.
Table 6-28
Parameter value
Connector
206
Description
Change request above the currently valid limit (example: a parameter value is too large for
the inverter power)
Change request not permitted (change is not permitted as the access code is not available)
PNU
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
Parameter value or connector
Bit 15 ... 0
Bit 15 ... 0
Number of the connector
PWE 1
0
0
32-bit value
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2017, FW V4.7 SP6, A5E34259001B AD
Page index
0 hex
80 hex
90 hex
20 hex
A0 hex
50 hex
F0 hex
74 hex
PWE 2
Bit 15 ... 8
Bit 7 ... 0
0
8-bit value
16-bit value
Bit 15 ... 10
Bit 9 ... 0
3F hex
The index or bit field
number of the connec‐
tor