Under development
Preliminary specification
Specifications in this manual are tentative and subject to change.
R8C/11 Group
Full status check
FMR06 =1
FMR07=1?
FMR07=
FMR06=
Full status check completed
Note 3: If FMR06 or FMR07 = 1, neither the Program nor Block Erase command is
accepted. Execute the Clear Status Register command before executing those
commands.
Figure 17.10 Full Status Check and Handling Procedure for Each Error
Rev.0.91
2003 Sep 08
YES
and
Command
sequence error
NO
NO
Erase error
0?
YES
NO
Program error
0?
YES
page 164 of 184
(1) Execute the Clear Status Register command to set
these status flags to "0".
(2) Re-execute the command after checking that it is
entered correctly.
(1) Execute the Clear Status Register command to set
the erase status flag to "0".
(2) Re-execute the Block Erase command.
Note 1: If the error still occurs, the block in error
cannot be used.
[During programming]
(1) Execute the Clear Status Register command to set
the program status flag to "0".
(2) Re-execute the Program command.
Note 2: If the error still occurs, the block in error
cannot be used.
17.4 CPU Rewrite Mode