Information - Keithley 6517B Reference Manual

Electrometer
Hide thumbs Also See for 6517B:
Table of Contents

Advertisement

Appendix E: IEEE-488 conformance

Information

The IEEE-488.2 standard requires specific information about how the Keithley Instruments Model
6517B Electrometer implements the standard. Paragraph 4.9 of the IEEE-488.2 standard
(Std 488.2-1987) lists the documentation requirements. The following table provides a summary of
the requirements, and provides the information or references the manual for that information.
IEEE-488 documentation requirements
Item
Number
Requirement
(1)
IEEE-488 interface function codes
(2)
Behavior of 6517B when the address
is set outside the range 0-30
(3)
Behavior of 6517B when valid address
is entered
(4)
Power-on setup conditions
(5)
Message exchange options:
(a)
Input buffer size
(b)
Queries that return more than one
response message unit
(c)
Queries that generate a response
when parsed
(d)
Queries that generate a response
when read
(e)
Coupled commands
(6)
Functional elements required for SCPI
commands
(7)
Buffer size limitations for block data
(8)
Syntax restrictions
(9)
Response syntax for every query
command
(10)
Device-to-device message transfer
that does not follow rules of the
standard
(11)
Block data response size
(12)
Common commands implemented by
6517B
(13)
Calibration query information
(14)
Trigger macro for *DDT
(15)
Macro information
(16)
Response to *IDN (identification)
(17)
Storage area for *PUD and *PUD?
(18)
Resource description for *RDT and
*RDT?
(19)
Effects of *RST, *RCL, and *SAV
E-2
Model 6517B Electrometer Reference Manual
Description or reference
See
IEEE-488 bus overview
Cannot enter an invalid address
Address changes and bus resets
Determine by :SYSTem:POSetup (see
command reference
(on page 14-1))
256 bytes
None
All queries (common commands and SCPI)
None
See the following table
Contained in SCPI command subsystems tables (see
SCPI command reference
(on page 14-1))
Block display messages: Top display = 20 characters
max, bottom display = 32 characters max
See
Remote operations
(on page 11-1)
See
Remote operations
(on page 11-1)
None
See
Remote operations
(on page 11-1)
See
Common commands
(on page 12-1)
See
Calibration procedure
(on page 15-1)
Not applicable
Not applicable
See
Common commands
(on page 12-1)
Not applicable
Not applicable
See
Common commands
(on page 12-1) and
Command Reference
(on page 14-1)
6517B-901-01 Rev. C / August 2015
(on page D-1)
SCPI
SCPI

Advertisement

Table of Contents
loading

Table of Contents