ptp announce-interval
ptp mode
ptp profile

ptp asymmetry-correction

Use ptp asymmetry-correction to configure asymmetric delay correction time.
Use undo ptp asymmetry-correction to restore the default.
Syntax
ptp asymmetry-correction { minus | plus } value
undo ptp asymmetry-correction
Default
The asymmetric delay correction time is 0 nanoseconds, which means delay correction is not
performed.
Views
Layer 2 Ethernet interface view, Layer 3 Ethernet interface view
Predefined user roles
network-admin
Parameters
minus: Subtracts the specified asymmetric delay correction value.
plus: Adds the specified asymmetric delay correction value.
value: Specifies the asymmetric delay correction value in the range of 0 to 2000000 nanoseconds.
Usage guidelines
This command is available only after you specify a PTP profile and a PTP mode.
Examples
# Configure the asymmetric delay correction time on FortyGigE 1/0/1 as 100 nanoseconds.
<Sysname> system-view
[Sysname] ptp profile 1588v2
[Sysname] ptp mode oc
[Sysname] interface fortygige 1/0/1
[Sysname-FortyGigE1/0/1] ptp asymmetry-correction plus 100
Related commands
ptp mode
ptp profile

ptp clock-source

Use ptp clock-source to configure parameters of the Bits clock.
Use undo ptp clock-source to restore the default.
Syntax
ptp clock-source { bits1 | bits2 } { accuracy acc-value | class class-value | time-source ts-value }