Event Syslog - HPE FlexFabric 5930 Series Network Management And Monitoring Command Reference

Hide thumbs Also See for FlexFabric 5930 Series:
Table of Contents

Advertisement

Usage guidelines
Use SNMP-Notification event monitor policies to monitor variables in SNMP notifications.
EAA executes an SNMP-Notification event monitor policy when the value of the monitored variable in
an SNMP notification meets the specified condition.
You can configure only one event for a monitor policy. If the monitor policy already contains an event,
the new event replaces the old event.
Examples
# Configure a CLI-defined policy test to monitor SNMP notifications that contain the MIB variable
1.3.6.1.4.1.25506.2.2.1.1.2.1.0. Enable the system to execute the policy and drop the SNMP
notifications if the variable value is admin.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event snmp-notification oid 1.3.6.1.4.1.25506.2.2.1.1.2.1.0 oid-val
admin op eq drop

event syslog

Use event syslog to configure a Syslog event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
event syslog priority level msg msg occurs times period period
undo event
Default
No Syslog event is configured.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
priority level: Specifies the lowest severity level for matching log messages. The level argument can
be an integer in the range of 0 to 7, or the word all, which represents any severity level from 0 to 7. A
lower number represents higher priority level. For example, specify a severity level of 3 to match log
messages from level 3 to level 0.
msg msg: Specifies a regular expression to match the message body, a string of 1 to 255 characters.
The log message must use the HPE format. For more information about log message formats, see
"Configuring the information center."
occurs times period period: Executes the policy if the number of log matches over an interval
exceeds the limit. The times argument specifies the maximum number of log matches in the range of
1 to 32. The period argument specifies an interval in the range of 1 to 4294967295 seconds.
Usage guidelines
Use Syslog event monitor policies to monitor log messages.
EAA executes a Syslog event monitor policy when the number of matching logs over an interval
reaches the limit.
319