Standard Auto-Tune (T01-01 = 0) Instructions - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Parameter
T01-09*
T01-10*
* If the value is not known, leave at default.
** See page 4-19 for Non-Rotational Auto-Tune instructions.

Standard Auto-Tune (T01-01 = 0) Instructions

This is a rotational Auto-Tuning method for the IMPULSE
Auto-Tuning on an unloaded or decoupled motor.
This method requires that the motor be unloaded or decoupled from the load with the brake
disengaged.
The instructions below will provide a step-by-step procedure to complete the non-rotational segment
of this Auto-Tune function:
1. In preparation for the Auto-Tune, the crane should be unloaded with minimal attachments. This
Auto-Tuning method requires free rotation of the unloaded motor, so decoupling the motor from
the load may be necessary.
2. Ensure the break is not set during the Auto-Tuning process.
3. Using the keypad, browse to the "Auto-Tuning" menu.
4. Choose "Standard Tuning" (T01-01 = 0) for the Tuning Mode.
5. Enter the nameplate motor characteristics (T01-02 – T01-08) until the "Tuning Ready?" screen is
reached.
6. Press the green "RUN" key to start the Auto-Tune. It will take up to a few minutes to complete.
During this time, the current will ramp up and down and a high pitched frequency may be audible
coming from the motor; this is normal. The motor will then begin a rotational cycle, which will
complete in one minute or less.
7. When the Auto-Tune has completed, the keypad display will display an "End Tune Successful"
message. Press the "ESC" key twice to exit.
NOTE:
If the STOP key is depressed during tuning, auto-tuning is interrupted and the motor
coasts to a stop. The data changed during tuning returns to its original values.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
4-18
Display
Description
Sets the no-load current for the
motor. After setting the motor
capacity to T01-02 and the motor
rated current to T01-04, this
parameter will automatically
No-Load Current
display the no-load current for a
standard 4 pole motor. Enter the
no-load current as indicated on
the motor test report or motor
nameplate.
Sets the motor rated slip. After
setting the motor capacity to T01-
02, this parameter will
automatically display the motor
Motor Rated Slip
slip for a 4 pole motor. Enter the
motor slip as indicated on the
motor test report or motor
nameplate.