Error
oPE07

Copy Function Related Faults

Tasks, Errors, and Troubleshooting

The table below lists the messages and errors that may appear when using the Copy function.
When executing the tasks offered by the Copy function, the operator will indicate the task being
performed. When an error occurs, a code appears on the operator to indicate the error. Note that
errors related to the Copy function do not trigger a multifunction output terminal that has been set up
to close when a fault or alarm occurs. To clear an error, simply press any key on the operator and the
error display will disappear.
Table 6-7 lists the corrective action that can be taken when an error occurs.
NOTE:
1. Whenever using the copy function, the drive should be fully stopped.
2. The drive will not accept a Run command while the Copy function is being executed.
3. Parameters can only be saved to a drive when the voltage class, capacity, control
method, and software version match.
Fault Display
CPEr
CPyE
CSEr
iFEr
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
6-28
Fault or Indicator
Card
Name/Description
A1-A3
Multi-function Analog
Input Selection Error.
Table 6-7: Copy Function Task and Error Displays
Fault or Indicator Name/Description
Control Method Mismatch. Control method
of the parameters to be loaded onto the drive
and the control method set to the drive do not
match.
Error Writing Data. Failed writing
parameters.
Copy Unit Error. Hardware fault.
Communication Error.
• A communication error occurred between
the drive and the operator or the USB copy
unit.
• A non-compatible cable is being used to
connect the USB Copy Unit and the drive.
Cause
• At least two analog
• Adjust H03-02,
input terminals are set
to the same function.
• Analog input terminal
and pulse train input
are set to the same
function.
Corrective Action
• Verify the control method for the parameters
to be loaded onto the drive and the control
method on the drive to which those
parameters will be written.
• Set the same control method using
parameter A01-02 and retry.
Attempt to write parameters again.
Replace the operator or the USB Copy Unit.
• Check the cable connection.
• Use the cable originally packaged with the
USB Copy Unit.
Possible Solution
H03-06, and H03-10
settings so functions
no longer conflict.