Hunting Prevention

Occasionally, in an application, resonance between the internal control system and the mechanical
system causes instability. This is called hunting, and may cause a crane to vibrate at a lower speed
(up to 30 Hz) and/or with a light load. The hunting prevention function monitors the motor flux and
uses a special control circuit to "smooth out" any peaks in the output current wave form.
Increase the set value of D11-02 when hunting is present while driving a light load. Decrease the set
value of D11-02 when the motor vibrates or stalls while driving a heavy load.
Parameter Display
D11-01
Hunt Prev Select
0
Disabled
1
Enabled
D11-02
Hunt Prev Gain
D11-03
Hunt Prev Time
D11-05
Rev Hunt Prev Gn
Table 5-53: Hunting Prevention Parameter Settings
Function
Enable/Disable Hunt
Prevention function
Hunting Prevention Gain
Hunting Prevention Time
Constant
Reverse Hunting Prevention
Gain
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Control
Range
Default
Method
0, 1
1
V/f
0.00–2.50
1.00
V/f
0–500ms
10
V/f
0.00–2.50
0.00
V/f
Model
G+
G+
G+
G+
5-67

Advertisement

Table of Contents
loading

Table of Contents