Keypad Key Selection

Parameter
O02-01
O02-02
O02-03
O02-04
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-124
Table 5-108: Keypad Key Selection Parameter Settings
Display
Function
LO/RE Key
Pressing the LO/RE Key once
displays: "Call Magnetek at 1-866-
624-7378".
0
Mode/Service
Control Method (A01-02)
Pressing the LO/RE Key a second
time:
Motion (A01-03)
Speed Reference (A01-04)
Pressing the LO/RE Key a third
time:
F1 and F2 Keys (H01-09 and
H01-10)
1
Local/Remote
Local/remote key is enabled
depressing the LO/RE key
switches operation command
between the digital operator and
the settings of B03-01 and B03-02.
Oper STOP Key
Selects the action when the digital
stop key is pressed.
0
Coast to Stop
(Immediate stop)
1
Decel to Stop
2
Use B3-03 Method
User Default Sel
0
No Change
1
Set Defaults
Memorizes up to 150 modified
parameters. User defaults can be
restored by setting
A1-05= "1110".
2
Clear All
Clear user defaults.
Inverter Model #
Enter the drive model. Setting
required only if installing a new
control board.
*Default determined by drive
capacity. Use normal duty current
ratings and drive nameplate.
62 2_0004
2003-G+/VG+S4
63 2_0006
2005-G+/VG+S4
64 2_0008
2007-G+/VG+S4
65 2_0010
2008-G+/VG+S4
66 2_0012
2011-G+/VG+S4
67 2_0018
2014-G+/VG+S4
68 2_0021
2017-G+/VG+S4
6A 2_0030
2025-G+/VG+S4
6B 2_0040
2033-G+/VG+S4
6D 2_0056
2047-G+/VG+S4
6E 2_0069
2060-G+/VG+S4
6F 2_0081
2075-G+/VG+S4
70 2_0110
2085-G+/VG+S4
72 2_0138
2115-G+/VG+S4
Range
Default
0, 1
0
0–2
0
0–2
0
00–FF
*