Quick Stop - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Quick Stop™

The Quick Stop Function provides an automatic Alternate Deceleration at Stop.
NOTE:
The Quick Stop Deceleration time differs from the normal deceleration time and is applied
only when the RUN command is removed.
Parameter
C01-01*
C01-02
* Initial value is determined by X-Press Programming (Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-16
Table 5-15: Quick Stop Parameter Settings
Display
Function
Quick Stop
Determines whether Quick Stop is
enabled
0
Disabled
1
Enabled
Quick Stop Time
Deceleration time during Quick
Stop function.
Figure 5-7: Quick Stop
Range
Default
0, 1
0
0.0–25.5 sec
1.0

Advertisement

Table of Contents
loading