Carrier Frequency

The Carrier Frequency group provides the ability to modify the drive's output carrier frequency and
drive overload level.
Parameter
D10-01
D10-02
D10-03
D10-04
D10-05
* Not available in VG+ (A01-02 = 3)
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-66
Consult Magnetek for drive derating before modifying the D10 group
parameters. Failure to do so may result in equipment damage.
Table 5-52: Carrier Frequency Parameter Settings
Display
Function
Heavy/NormalDuty
Constant Torque/Variable Torque
Selection
0
Heavy Duty
1
Normal Duty
CarrierFreq Sel
Carrier Frequency Selection
1
Fc=2.0kHz
2
Fc=5.0kHz
3
Fc=8.0kHz
4
Fc=10.0 Hz
5
Fc=12.5kHz
6
Fc=15.0kHz
7
Swing PWM1*
8
Swing PWM2*
9
Swing PWM3*
A
Swing PWM4*
F
User Defined
Determined by D10-03 through
D10-05
CarrierFreq Max
Determines the carrier frequency
upper limit.
CarrierFreq Min
Determines the carrier frequency
lower limit (V/f Control only).
CarrierFreq Gain
Carrier Frequency Gain (V/f
Control only).
C A U T I O N
Range
0, 1
1–9, A, F
1.0–15.0 kHz
1.0–15.0 kHz
0–99
Default Model
0
G+/VG+
1
G+/VG+
2.0
G+/VG+
2.0
G+
0
G+