Coast To Stop (B03-03=1); Decel W/Timer (B03-03=4) - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Coast to Stop (B03-03=1)

Upon removal of the FWD or REV run command, the motor starts to coast and the electric brake
sets.

Decel w/Timer (B03-03=4)

NOTE:
This option is only available in traverse motion.
Upon run command removal, the motor decelerates to stop. The brake delays for a time interval
(C12-02) before it is set. This option reduces brake wear for applications that involve frequent
stopping and starting.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-8
Run
Command
Frequency
Output
Brake
Output
Figure 5-3: Coast to Stop
Figure 5-4: Decel w/Timer