Reverse Plug Simulation™

The Reverse Plug Simulation provides an automatic alternate deceleration time/acceleration time
at a change direction command. The deceleration time and the acceleration time are set
independently of the normal acceleration and deceleration times.
NOTE:
Reverse Plug Simulation is not available in MLB (standard) Hoist.
Parameter
Display
C01-03
Reverse Plug
0
Disabled
1
Enabled
C01-04
Rev-Plg Dec Time
C01-05
Rev-Plg Acc Time
NOTE:
A setting of 0.0 in C01-05 will cause B05-01 to be used during acceleration.
Table 5-16: Reverse Plug Simulation
Function
Determines whether Reverse Plug
Simulation is enabled.
Deceleration time during Reverse
Plug Simulation.
Acceleration time during Reverse
Plug Simulation.
Figure 5-8: Reverse Plug Simulation
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
Default
0, 1
0
0.0–25.5 sec
2.0
0.0–25.5 sec
0.0
5-17