Control Circuit Terminals - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Control Circuit Terminals

The table below outlines the functions of the control circuit terminals.
Terms:
Multi-Function Digital Input (MFDI)
Multi-Function Digital Output (MFDO)
Multi-Function Analog Input (MFAI)
Multi-Function Analog Output (MFAO)
Table 3-8: Control Circuit Terminals
Classification
Terminal
S1
S2
S3
S4
Digital
S5
Input Signals
S6
S7
S8
X2
+V
-V
A1
Analog
Input Signals
A2
A3
AC
E(G)
M0
M1
M2
M3
Digital
M5
Output Signals
M6
MA
MB
MC
IMPULSE®•G+ & VG+ Series 4 Instruction Manual - February 2017
3-20
Signal Function
MFDI 1
MFDI 2
MFDI 3
MFDI 4
Programmable Multi-function
digital inputs (H01-01 to H01-08)
MFDI 5
MFDI 6
MFDI 7
MFDI 8
MFDI Common
Common for control signal
Power supply for
Positive supply for analog inputs
analog inputs
Power supply for
Negative supply for analog inputs
analog inputs
Multi-function analog input (H03-
MFAI 1
02)
Multi-function analog input (H03-
MFAI 2
10)
Multi-function analog input (H03-
MFAI 3
06)
Analog Common
Common for analog signal
Ground for shielded
Earth ground
lines and option cards
Multi-function digital output (H02-
MFDO 1
01)
Multi-function digital output (H02-
MFDO 2
02)
Multi-function digital output (H02-
MFDO 3
03)
Fault annunciate
Terminals MA & MC N/O; closed
Terminals MA-MC:
at major faults
N/O
Terminals MB & MC N/C open at
Terminals MB-MC:
major faults
N/C
Description
Photo-coupler isolation
120 VAC
+10.5 VDC, 20 mA
-10.5 VDC, 20 mA
-10 to +10 V (20kΩ)
0 to +10 V (20kΩ)
-10 to +10 V (20kΩ)
0 to +10 V (20kΩ)
4 to 20 mA (250Ω)
-10 to +10 V (20kΩ)
0 to +10 V (20kΩ)
Form A Relay:
250 VAC (48 VAC for CE), 1 A
30 VDC, 1 A
Form A Relay:
250 VAC (48 VAC for CE), 1 A
30 VDC, 1 A
Form A Relay:
250 VAC (48 VAC for CE), 1 A
30 VDC, 1 A
Form C Relay:
250 VAC (48 VAC for CE), 1 A
30 VDC, 1 A
Signal Level
0 V
0 V

Advertisement