User Parameters (A02-01 Through 32) - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

User Parameters (A02-01 through 32)

The user can select up to 32 parameters for quick-access programming. By setting the user access
level (A01-01) to "User Program", only the parameters selected in function A2 can be accessed by
the user. To assign a parameter as a user parameter, go to the A2 level in the initialize menu. Once
the A2 parameters are set and A01-01 is programmed to "User Program", only the parameters
visible in the program menu will be assigned to an A2 parameter.
The A2 group is pre-loaded with the settings listed in table 4-10, based on A01-03.
A01-03
Favorite
--
A02-01
A02-02
A02-03
A02-04
A02-05
B03-04: Change Rotation
A02-06
B05-01: Accel Time 1
A02-07
B05-02: Decel Time 1
A02-08
C01-03: Reverse Plug
A02-09
C01-04: Rev-Plg Dec Time
A02-10
C01-05: Rev-Plg Acc Time
A02-11
C02-01: MicroSpd Gain 1
A02-12
E01-03: V/f Selection
A02-13
E02-01: Motor Rated FLA
A02-14
H01-06: Terminal S6 Select
A02-15
H01-07: Terminal S7 Select
A02-16
H01-08: Terminal S8 Select
A02-17
H02-03: Terminal M5/M6 Select
A02-18
H03-02: Terminal A1 Function Select
A02-19
H04-02: Terminal FM Gain
A02-20
A02-21
A02-22
A02-23
A02-24
A02-25
A02-26
A02-27
A02-28
A02-29
A02-30
A02-31
A02-32
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
4-16
Table 4-10: Application Quick Set
0
Traverse
B01-01: Speed 1
B01-02: Speed 2
B01-03: Speed 3
B01-04: Speed 4
B01-05: Speed 5
--
--
--
--
--
--
--
--
--
--
--
--
--
1
Std Hoist
B01-01: Speed 1
B01-02: Speed 2
B01-03: Speed 3
B01-04: Speed 4
B01-05: Speed 5
B03-04: Change Rotation
B05-01: Accel Time 1
B05-02: Decel Time 1
C02-01: MicroSpd Gain 1
C03-01: UL1 Speed
C03-04: LL1 Speed
C06-01: Swift-Lift
C06-02: SwiftLift FWDSpd
C06-03: SwiftLift REVSpd
C06-04: SL FWD Current/Torque
C06-05: SL REV Current/Torque
C06-06: SL Enabling Spd
E01-03: V/F Selection
E01-04: Max Frequency
E02-01: Motor Rated FLA
H01-06: Terminal S6 Select
H01-07: Terminal S7 Select
H01-08: Terminal S8 Select
H02-03: Terminal M5/M6 Select
H03-02: Terminal A1 Function Select
H04-02: Terminal FM Gain
--
--
--
--
--
--
--
2
NLB Hoist
B01-01: Speed 1
B01-02: Speed 2
B01-03: Speed 3
B01-04: Speed 4
B01-05: Speed 5
B03-04: Change Rotation
B05-01: Accel Time 1
B05-02: Decel Time 1
C01-01: Quick Stop
C01-02: Quick Stop Time
C02-01: MicroSpd Gain 1
C03-01: UL1 Speed
C03-04: LL1 Speed
C06-01: Ultra-Lift
C06-02: UltraLift FWDSpd
C06-03: UltraLift REVSpd
C06-04: UL FWD Torque
C06-05: UL REV Torque
C08-03: Min Brk Rel Trq
C08-10: Load Float Time
C08-11: Brake Set Delay
C08-14: Brake Hold Speed
F01-01: PG1 Pulses/Rev
F01-05: PG1 #Gear Teeth2
H01-06: Terminal S6 Select
H01-07: Terminal S7 Select
H01-08: Terminal S8 Select
H02-03: Terminal M5/M6 Select
H03-02: Terminal A1 Function Select
H04-02: Terminal FM Gain
--
--
--

Advertisement