Digital Output (DO-A3) and S4IO Option Set-up

Selects the multi-function digital output settings for channels 1 through 8 of the DO-A3 and S4IO
option cards.
Parameter
F05-01*
F05-02*
F05-03*
F05-04*
F05-05*
F05-06*
F05-07*
F05-08*
F05-09
* See Table 5-76 for MFDO selections.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-80
Table 5-67: Digital Output Set-Up Parameter Settings
Display
DO Ch1 Select
DO Ch2 Select
DO Ch3 Select
DO Ch4 Select
DO Ch5 Select
DO Ch6 Select
DO Ch7 Select
DO Ch8 Select
DO Function Sel
Selects how the DO-A3 option
card will work with the drive.
0
8ch Individual
1
Binary Output
2
8ch Selected
Terminal Designation
DO-A3
S4IO
M1-PC
O1-O2
M2-PC
O3-O2
M3-PC
O4-O5
M4-PC
O6-O5
M5-PC
--
M6-PC
--
M1-M2
--
M3-M4
--
Range
Default
0–148
F
0–148
F
0–148
F
0–148
F
0–148
F
0–148
F
0–148
F
0–148
F
0–2
2