Reference Limits - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Reference Limits

These parameters limit the frequency range as a percentage of maximum output frequency (E01-
04). If the lower limit is below the DC Inj Start Freq (D01-01), then operation will continue according
to B03-05.
An alternate upper limit frequency can be used during operation when a Multi-Function Digital Input
(MFDI) is set to 59 (Alt F-Ref Up Lmt) and the MFDI is on.
Parameter
Display
B02-01
Ref Upper Limit
B02-02
Ref Lower Limit
B02-03
Ref1
Lower Limit
B02-04
Alt Upper Limit
* Initial value is determined by X-Press Programming (Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
Figure 5-1: Setting Frequency Upper and Lower Limits
Table 5-3: Reference Limit Parameter Settings
Function
Sets as a percentage of the
maximum output frequency (E01-
04), which determines the
maximum frequency at which the
drive is able to run.
Sets as a percentage of the
maximum output frequency (E01-
04), which determines the
minimum master frequency
reference only.
Sets as a percentage of the
maximum output frequency (E01-
04), which determines the
minimum frequency at which the
drive is able to run.
Alternate of B02-01 set by
MFDI=59.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
Default
0.0–110.0%
100.0*
0.0–110.0%
0.0
0.0–110.0%
2.0*
0.0–110.0%
0.0
5-5