Torque Limit

®
IMPULSE
•G+ and VG+ Series 4 drives dynamically control the torque output of the motor while
running. The Torque Limit Function limits the amount of torque the motor is capable of producing in
Open and Closed loop vector control.
Forward Motoring (I)
Forward Regenerating (II)
Reverse Motoring (III)
Reverse Regenerating (IV)
Parameter Display
C07-01
Trq Limit FWD
C07-02
Trq Limit REV
C07-03
Trq Lmt FWD Rgn
C07-04
Trq Lmt REV Rgn
x = Available in the specified drive/control method
Table 5-30:
Torque Limit Parameter Settings
Function
FORWARD torque limit
REVERSE torque limit
Regenerative torque limit at
FORWARD
Regenerative torque limit at
REVERSE
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
Default
0–300%
150
0–300%
150
0–300%
180
0–300%
180
Model
G+/VG+
G+/VG+
G+/VG+
G+/VG+
5-33