Drive Derating Data
Temperature Derating
To ensure the maximum performance life, the drive output current must be derated when the drive is
installed in areas with high ambient temperature or if drives are mounted side-by-side in a cabinet. In
order to ensure reliable drive overload protection, set parameters L08-12 and L08-35 according to
the installation conditions. Contact Magnetek for derating curves.
IP00/Open-Chassis Enclosure
Drive operation between -10°C to +60°C (14°F to 140°F) allows CMAA Class F continuous current
without derating.
Side-by-Side Mounting
Drive operation between -10°C and 30°C (14°F to 86°F) allows CMAA Class F continuous current
without derating. Operation between 30°C and 50°C (86°F to 122°F) requires output current
derating.
Dimensions for IP00/Open Chassis Enclosures
IMPULSE®•G+ & VG+ Series 4 Instruction Manual - February 2017
2-10