Digital Input Option Set-up (DI-A3 and S4IO)

Selects the digital input controls for either the DI-A3, S4I, or S4IO option when installed.
Parameter
Display
Digital In Sel
C09-01
0
1
2
5
Parameter
C09-02*
C09-03*
C09-04*
C09-05*
C09-06*
C09-07*
C09-08*
C09-09*
C09-10*
C09-11*
C09-12*
C09-13*
C09-14*
C09-15*
C09-16*
C09-17*
* See Table 5-72 for MFDI selections. The following input functions will not operate on an input option board: 20~20F, 31, 34, 35, 47, 80,
or 81.
Table 5-34: Digital Input Set-up Parameter Settings
Function
Provides additional programmable
MFDI
Disabled
No additional MFDI are being
used.
Enabled S4IO
S4IO or S4I card is installed
Enabled DI-A3
DI-A3 card is installed
Serial
Modbus RTU using
C09-02–C09-17
Terminal Designation
Display
DI-A3
DIO Terminal 1
0
DIO Terminal 2
1
DIO Terminal 3
2
DIO Terminal 4
3
DIO Terminal 5
4
DIO Terminal 6
5
DIO Terminal 7
6
DIO Terminal 8
7
DIO Terminal 9
8
DIO Terminal 10
9
DIO Terminal 11
A
DIO Terminal 12
B
DIO Terminal 13
C
DIO Terminal 14
D
DIO Terminal 15
E
DIO Terminal 16
F
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
0–2, 5
Range**
S4I
S4IO
I1
I1
00–FF
I2
I2
00–FF
I3
I3
00–FF
I4
I4
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
--
--
00–FF
Default
0
Default
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
0F
5-43