Automatic Fault Reset - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Automatic Fault Reset

When a fault occurs during operation, the IMPULSE
an auto reset operation to automatically reset the fault.
Parameter
L09-01
L09-02
L09-03
L09-04*
L09-05*
L09-06
* To program constant L09-04 and L09-05, refer to the example on the following page and follow steps 1
through 4:
1. Assign 1 to each fault code to enable the auto reset.
2. Assign 0 to each fault code to disable the auto reset.
3. Convert all Digits (1 to 4) from binary to hex.
4. Program L09-04 and L09-05 by entering the hex number obtained from step 3.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-118
Table 5-101: Automatic Reset Parameter Settings
Display
Function
Reset Select
Activates the fault auto-reset
function.
0
Disabled
1
Enabled
Reset Attempts
Sets the number of reset attempts.
Reset attempt counter is returned
to zero if no faults occur within a
ten minute period.
Reset Time
Sets the reset starting time.
Reset Flt Sel 1
Reset Fault Select 1.
Reset Flt Sel 2
Reset Fault Select 2.
Flt Contact Sel
Fault contact operation during
reset attempts
0
Flt Outp Disabld
1
Flt Outp Enabled
Figure 5-26: Automatic Fault Reset
®
•G+ and VG+ Series 4 can be programmed for
Range
0, 1
0–10
0.5–600.0 sec
0–FFFF
0–FFFF
0, 1
Default
1
3
0.5
4001
E000
0