Terminal Parameters

H1 Digital Inputs
H2 Digital Outputs
H3 Analog Inputs
H4 Analog Outputs
H5 Serial Communication Set-up
H6 Pulse Input/Output

Digital Inputs

The IMPULSE
numerous functions. The following table lists the function selections for the multi-function digital
inputs (terminals S1 to S8) and indicates the control methods during which each function can be
enabled. An OPE03 error will occur if a function is programmed in more than one terminal at the
same time.
Parameter
H01-01
H01-02
H01-03
H01-04
H01-05
H01-06
H01-07
H01-08
H01-14
* Initial value is determined by X-Press Programming (Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
Table 5-72: Multi-Function Digital Inputs (MFDI) selectable for H01-0x and C09-0x
Display
0
Multi-Step Ref 2
1
Multi-Step Ref 3
2
Multi-Step Ref 4
3
Multi-Step Ref 5
4
Speed Hold 2
5
Accel Command
6
Upper Lmt 1 N.O.
7
Upper Lmt 2 N.O.
8
Lower Lmt 1 N.O.
9
Lower Lmt 2 N.O.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-86
®
•G+ and VG+ Series 4 has eight multi-function digital inputs for the set-up of
Table 5-71:
Display
Function
Term S1 Select
Selects the multi-function inputs.
Reference Table 5-72
Term S2 Select
Reference Table 5-72
Term S3 Select
Reference Table 5-72
Term S4 Select
Reference Table 5-72
Term S5 Select
Reference Table 5-72
Term S6 Select
Reference Table 5-72
Term S7 Select
Reference Table 5-72
Term S8 Select
Reference Table 5-72
Alt Ref Override
Alternate Frequency Reference
Override. When enabled, and an input
0
Disabled
of H01-xx = 1F is true, will switch
between Frequency Reference
1
Enabled
Source 2 (B03-15) and the terminals
(B01-xx).
Function
Multi-Step Reference 2
Multi-Step Reference 3
Multi-Step Reference 4
Multi-Step Reference 5
Speed Hold 2 (2nd Step of Three-Step Infinitely Variable)
Accel Command (2nd Step of Two-Step Infinitely Variable or 3rd Step of
Three-Step Infinitely Variable)
Upper Limit - Slow Down; Normally Open. UL1 - blinking
Upper Limit - Stop; Normally Open. UL2 - blinking
Lower Limit - Slow Down; Normally Open. LL1 - blinking
Lower Limit - Stop; Normally Open. LL2 - blinking
Digital Inputs Parameter Settings
Range
Default
0–81
80
(FWD)
0–81
81
(REV)
0–81
*
0–81
*
0–81
*
0–81
*
0–81
*
0–81
*
0, 1
0