Accel/Decel Time Switching Frequency

Accel/Decel times can be changed automatically without using multi-function inputs. When multi-
function digital inputs are set for Accel/Decel selection, this command has priority over automatic
change of Accel/Decel.
Table 5-11: Accel/Decel Time Switching Frequency Parameter Settings
Parameter
Display
B05-05
Acc Time N Chg
B05-06
Dec Time N Chg
B05-08
Fast Stop Time
B05-10
Acc/Dec SW Freq
B05-11
SW Freq. Compare
0
Lower SW Freq
1
Upper SW Freq
B05-12
Accel Time 3
B05-13
Decel Time 3
B05-14
Accel Time 4
B05-15
Decel Time 4
B05-16
Acc/Dec Ext Rang
0
Disabled
1
Enabled
* Range is extended to 0.0–6000.00 when B05-16 = 1.

Jump Frequencies

This function allows the "jumping" of critical frequencies so that the motor can operate without
resonant vibrations caused by some machine systems. This function is also used for deadband
control. Setting the value to 0.0 Hz disables this function.
Parameter
Display
B08-01
Jump Freq 1
B08-02
Jump Freq 2
B08-03
Jump Freq 3
B08-04
Jump Bandwidth
Function
Sets Acceleration time at Acc/Dec
Switch Frequency (B05-10)
Sets Deceleration time at Acc/Dec
Switch Frequency (B05-10)
Sets deceleration time for
complete stop at external fault.
See "External Fault Response
Selection" on page 5-96.
Determines acceleration/
deceleration time settings
Determines when Acceleration
Time and Deceleration Time at
Speed Switch Hz is enabled;
0: B05-05/B05-06 enabled, U01-02 < B05-10
1: B05-05/B05-06 enabled, U01-02 > B05-10
Acceleration time 3 enabled when
H01-xx = 1B.
Deceleration time 3 enabled when
H01-xx = 1B.
Acceleration time 4 enabled when
H01-xx = 1C.
Deceleration time 4 enabled when
H01-xx = 1C.
Enables extended range of Acc/
Dec Params: B05-01–B05-04,
B05-12–B05-15, C03-02, C03-03,
C03-05 and C03-06
Range = 0.0–25.5
Range = 0.0–6000.0
Table 5-12: Jump Frequencies Parameter Settings
Function
First of three jump frequencies.
Second of three jump frequencies. 0.0–150.0 Hz
Third of three jump frequencies.
Jump frequency reference
bandwidth.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
Default
0.0–25.5 sec
2.0
0.0–25.5 sec
2.0
0.0–25.5 sec
0.5
0.0–E01-04
0.0
0, 1
1
0.0–25.5 sec*
3.0
0.0–25.5 sec*
3.0
0.0–25.5 sec*
3.0
0.0–25.5 sec*
3.0
0, 1
0
Range
Default
0.0–150.0 Hz
0.0
0.0
0.0–150.0 Hz
0.0
0.0–20.0 Hz
1.0