F1 and F2 Keys Function Selection

The F1 and F2 keys on the keypad have the ability of being programmed with specific functions to
imitate digital inputs. The table below displays the various settings, which are valid for these buttons.
To operate a function assigned to the F1 or F2 key, the respective button must be held down.
Releasing the button will stop the function. Be cautious when operating these keys, and
remember that the STOP key will override and stop all functions.
To quickly view the functions assigned to both buttons, press the LO/RE key three times.
Table 5-73: F1 and F2 Function Selection Parameter Settings
Parameter
Display
H01-09
F1 Key Selection
H01-10
F2 Key Selection
Table 5-74: F1 and F2 keys function selectable for H01-09 and H01-10
Display
0F Not Used
48 Flt Latch Reset
53 Comm Test Mode
5A MaintenanceReset
61 Brake Test
67 Hook Height Home
69 LC Bypass N.O.
73 LL2/UL2 Bypass
74 LL/UL Bypass
Function
Function selection for F1 key
Function selection for F2 key
Function
Instruction
No function -
--
terminal is disabled
When a fault is
Press F1 or F2 once to pre-
latched, toggle this
start Fault Latch Reset. A
input ON and then
confirm message will appear,
OFF to clear the
and the same key press will
fault.
be required once more to
reset a latched fault.
Communication Test
Hold down the F1 or F2 key
Mode - loopback test
for 2–3 seconds to initiate the
of Modbus RS-422/
Comm Test.
485 interface
Resets Maintenance
Press F1 or F2 once to pre-
Timer (C12-05, C12-
start Maintenance Timer
06, U01-52)
Reset. A confirm message will
appear, and the same key
press will be required once
more to reset the
Maintenance Timer.
Motor pushes
Hold down the F1 or F2 key to
against brake up to
initiate the Brake Test.
programmable
torque setting C08-
24 at programmable
frequency C08-25.
Disabled PG Faults
during this condition.
Used with C03-14 -
Press F1 or F2 once to pre-
Height Measurement
start Hook Height Home. A
function.
confirm message will appear,
and the same key press will
be required once more to
home the Hook Height.
Disables Load
Hold down the F1 or F2 key to
Check and clears
initiate the LC Bypass.
any LC faults.
Bypass Limit MFDI
Hold down the F1/F2 key to
and EPLS
initiate LL2/UL2 Bypass.
Bypass MFDI and
Hold down the F1/F2 key to
EPLS
initiate LL/UL Bypass.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
Default
0F–74
0F
0F–74
0F
Alert/Confirm Message
--
Confirm?
Flt Latch Reset
Running:
Comm Test Mode
Confirm?
MaintenanceReset
Running:
Brake Test
Confirm?
Hook Height Home
Running:
LC Bypass N.O.
Running:
LL2/UL2 Bypass
Running:
LL/UL Bypass
5-89