Analog Input (Ai-A3) Option Set-Up - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Analog Input (AI-A3) Option Set-up

Sets CH1 to CH3 input functions when AI-A3 option is connected.
When the 3CH individual input is used, parameter B03-01 is automatically set to "1" (frequency
reference from control circuit terminal). The option/inverter reference selection, which is selected by
a multi-function digital input (H01-xx= "1F"), is disabled when using the AI-A3 option.
Parameter
F02-01
F02-02
F02-03
Setting
0
1
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-78
Table 5-63: Analog Input Option Parameters
Display
AI Function Sel
0
3ch Individual
1
3ch Addition
AI Input Gain
AI Input Bias
Table 5-64: Analog Input Option Configuration
Function
3-channel individual input
(factory default)
3-channel addition input
Function
Determines whether the 3-channel
input selection is individual or
addition. See Table 5-63.
Sets the gain for the input signal to
the analog card.
Sets the bias for the input signal to
the analog card.
CH1 (V1 to AC)
CH2 (V2 to AC)
Substitute for
Substitute for
terminals V1 & AC
terminals V2 & AC
Sum of CH1 to CH3 input values is used as the frequency reference
value
Range
Default
0, 1
0
-999.9–999.9%
100.0
-999.9–999.9%
0.0
CH3 (V3 to AC)
Substitute for
terminals V3 & AC

Advertisement

Table of Contents
loading

Table of Contents