Speed/Torque Control Switching

Speed control or torque control is used in traverse applications and can be selected "on the fly" with
the VG+ drive by using the multi-function input speed/torque control selection command (H01-xx =
34).
Terminal Number
S1 - S8
A1
A3/A2
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-62
Table 5-49:Speed/Torque Control Switch Parameters
Parameter
Number
Setting
H01-01–H01-08
34
B03-01
1
D05-03
1
H03-06/H03-10
13
Figure 5-21: Speed/Torque Control Selection Timing Diagram
Description
Speed/torque control selection
Frequency reference selection (terminals A1,
A2, or A3)
Speed limit selection (terminals A1, A2, or A3)
Torque reference/torque limit