Acceleration/Deceleration - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

Acceleration/Deceleration

Acceleration time sets the time necessary for the output frequency to accelerate from 0 Hz to
maximum output frequency (E01-04). Deceleration time sets the time necessary for the output
frequency to decelerate from the maximum output frequency (E01-04) to 0 Hz.
Parameter
B05-01
B05-02
B05-03
B05-04
* Initial value is determined by X-Press Programming (Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
** Range is extended to 0.0–6000.00 when B05-16 = 1.
Figure 5-5: Normal Accel/Decel Time and Multiple Accel/Decel Changeover
NOTE:
Assume the constant B03-03 is set to "0" (Decel to Stop).
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-12
Table 5-10: Acceleration/Deceleration Parameter Settings
Display
Function
Accel Time 1
Sets acceleration time.
Decel Time 1
Sets deceleration time.
Accel Time 2
Acceleration time 2 enabled when
H01-xx = 1A.
Decel Time 2
Deceleration time 2 enabled when
H01-xx = 1A.
Range
Default
0.0–25.5 sec**
5.0*
0.0–25.5 sec**
3.0*
0.0–25.5 sec**
10.0
0.0–25.5 sec**
10.0

Advertisement

Table of Contents
loading