S-Curve Acceleration/Deceleration - Magnetek Impulse G+ series 4 Instruction Manual

Adjustable frequency crane controls
Hide thumbs Also See for Impulse G+ series 4:
Table of Contents

Advertisement

S-Curve Acceleration/Deceleration

An S-Curve pattern is used to reduce shock and provide smooth transitions during machine
acceleration and deceleration. S-Curve characteristic time is the time from the output frequency to
the set accel/decel time. See S-Curve Characteristic timing diagrams below and on the following
page.
Table 5-51: S-Curve Acceleration/Deceleration Parameter Settings
Parameter
Display
D09-01
SCrv Acc @ Start
D09-02
SCrv Acc @ End
D09-03
SCrv Dec @ Start
D09-04
SCrv Dec @ End
* Initial value is determined by X-Press Programming (Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
The figure below shows FWD/REV run switching during deceleration to stop. The S-curve function
will add time to the acceleration and deceleration. Time to accelerate from the minimum frequency to
the maximum frequency (total acceleration) is:
Time to decelerate from the maximum frequency to the minimum frequency (total deceleration) is:
Figure 5-23: S-Curve Characteristic-FWD/REV Operation
Function
Sets the S-Curve at the beginning
of the Accel time.
Sets the S-Curve at the end of the
Accel time.
Sets the S-Curve at the beginning
of the Decel time.
Sets the S-Curve at the end of the
Decel time.
Total Acceleration =
Total Deceleration =
CAUTION Accel/Decel times will be extended.
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
Range
0.00–10.00 sec
0.00–10.00 sec
0.00–10.00 sec
0.00–10.00 sec
C A U T I O N
Default
0.20*
0.20*
0.20*
0.20
5-65