Profibus-DP Communication Option Card Set-up

Settings for the Profibus-DP communication option card SI-P3.
Parameter
F06-01
F06-02
F06-03
F06-04
F06-06
F06-07
F06-08
F06-30
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-82
Table 5-69: Communication Option Card Parameter Settings
Display
Function
Comm Bus Flt Sel
Stopping method at
communication error.
0
Decel to Stop
1
Coast to Stop
2
Fast-Stop
3
Use B3-03 Method
4
Alarm Only
EF0 Detection
Option External Fault
0
Always Detected
1
Only During Run
EF0 Fault Action
Option External Fault
0
Decel to Stop
1
Coast to Stop
2
Fast-Stop
3
Use B3-03 Method
4
Alarm Only
BUS Err Det Time
Set the maximum time the drive
should wait for a communication
error to occur (bUS).
Torq Ref/Lmt Sel
Torque Reference Limit Selection
(FLV only)
0
Disabled
1
Enabled
Fref PrioritySel
Selects how multi-step speed
inputs are treated when the
NetRef command is set.
0
Net/Com REF
Multi-step reference disabled
1
MultiStep Speed
Multi-step reference enabled
Com Prm Init Sel
Determines whether
communication-related
parameters (F06-xx and F07-xx)
are reset when the drive is
initialized using A01-05
0
Init Com Prms
Communication-related
parameters (F06-xx and F07-xx)
are not reset when the drive is
initialized using A01-05.
1
No Init Com Prms
Reset all communication-related
parameters (F06-xx and F07-xx)
when the drive is initialized using
A01-05.
PB Node Address
Sets the node address if the
Profibus-DP option card is
installed
Range
Default
0–4
1
0, 1
0
0–4
1
0.0–5.0 sec
2.0
0, 1
0
0, 1
0
0, 1
0
0–125
0