7. Run the connected motor with the Jog function and check the Jog speed or Jog torque.
Note
When you run a servo motor with an incremental encoder in JOG mode, the servo motor makes a short buzzing sound
indicating that it is identifying the magnetic pole position of the rotor.
4.8.1.2

Configuring Drive Bus addresses

To configure the Drive Bus addresses on the SINAMICS V70 drive, set parameter p0918 (default = 10) with the drive BOP
as required. You must set a proper address according to the actual application of the drive.
● 11: X axis
● 12: Y axis (or additional axis for the turning variant of the control system)
● 13: Z axis
● 14: Digital spindle (SINAMICS V70 spindle drive only)
● 15: Additional axis
You can also set the Drive Bus address with the auxiliary function menu on the drive BOP. For more information, see
Section "Setting Drive Bus address (Page 467)".