Alarm Cancel/Reset And Reaction; Editing Plc Alarm Texts - Siemens SINUMERIK 808D ADVANCED Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

6.8.1

Alarm cancel/reset and reaction

Conditions of alarm cancel/reset
After the cancel of an alarm, you need to press one of the following two keys to clear the alarm finally.
Then the alarm displayed will disappear by itself.
or
Alarm reaction
There are the following two ways for alarm reaction.
PLC reaction: the PLC program detects the reaction through the corresponding PLC interface, such as canceling the axis
enable when giving an alarm.
NC reaction: every alarm has an eight-bit configuration MD14516[0] to [127]. You can set the cancelation condition and
alarm reaction for every alarm according to the actual condition. The system then makes the corresponding reaction when
the alarm begins.
6.8.2

Editing PLC alarm texts

Creating or editing alarm texts correctly and reasonably can make users clearly realize and understand the reason of a PLC
alarm and then locate and resolve breakdown.
You can edit a PLC user alarm by using the following two methods:
● Editing via a USB memory stick
● Editing directly on the HMI
Editing a PLC user alarm via a USB memory stick
1.
2.
+
3.
220
Insert the USB stick into the USB interface on the front panel of the PPU.
Select the system data operating area.
Press this softkey to open the system data window.
Commissioning Manual
01/2017