A.1.1.3

Actual status display

You can monitor the following drive states by using the operating panel after power-on:
● Servo off
● Actual speed
● Torque
● Voltage
If the servo enable signal is available, actual drive speed is displayed by default; otherwise, "S OFF" (servo off) is displayed.
With p29002, you define which of the following drive operating status data is to be displayed on the BOP.
Value
0 (default)
1
2
Note
Make sure you save p29002 after modification.
A.1.1.4

Basic operations

Editable parameters
All P parameters under the "Para" menu are editable parameters.
Read-only parameters
All r parameters under the "Data" menu are read-only parameters.
Parameters with index
Some parameters have several indices. Each index has its own meaning and corresponding value.
Parameters without index
All parameters that do not have indices are parameters without index.
Editing parameters
You can edit a parameter value in two methods:
● Method 1: change the value directly with the UP or DOWN button
● Method 2: move the cursor to a digit with the SHIFT button, then change the digit value with the UP or DOWN button
464
Meaning
Actual speed
DC voltage
Actual torque