Fault
F1002: Internal software
error
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F1003: Acknowledgement
delay when accessing the
memory
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F1015: Internal software
error
Reaction: OFF2
Acknowledgement: POWER
ON
F1018: Booting has been
interrupted several times
Reaction: NONE
Acknowledgement: POWER
ON
F1030: Sign-of-life failure for
master control
Reaction: OFF3
Acknowledgement:
IMMEDIATELY
F1611: SI CU: Defect de-
tected
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F1910: Drive Bus: Setpoint
timeout
Reaction: OFF3
Acknowledgement:
IMMEDIATELY
F1911: Drive Bus clock cycle
synchronous operation clock
cycle failure
Reaction: OFF1
Acknowledgement:
IMMEDIATELY
488
Cause
An internal software error has occurred.
A memory area was accessed that does
not return a "READY".
An internal software error has occurred.
Module booting was interrupted several
times. As a consequence, the module
boots with the factory setting.
Possible reasons for booting being inter-
rupted:
Power supply interrupted.
CPU crashed.
Parameterization invalid.
After this fault is output, then the module is
booted with the factory settings.
For active PC master control, no sign-of-
life was received within the monitoring
time.
The drive-integrated "Safety Integrated"
(SI) function on the Control Unit (CU) has
detected an error and initiated an STO
The reception of setpoints from the Drive
Bus interface has been interrupted.
Bus connection interrupted.
Controller switched off.
Controller set into the STOP state.
The global control telegram to synchronize
the clock cycles has failed - in cyclic oper-
ation - for several Drive Bus clock cycles
or has violated the time grid specified in
the parameterizing telegram over several
consecutive Drive Bus clock cycles.
Remedy
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
Carry out a POWER ON (power off/on).
After switching on, the module reboots from
the valid parameterization (if available).
Restore the valid parameterization.
Examples:
Carry out a first commissioning, save, carry
out a POWER ON (switch-off/switch-on).
Load another valid parameter backup (e.g.
from the memory card), save, carry out a
POWER ON (switch-off/switch-on).
Note:
If the fault situation is repeated, then this fault
is again output after several interrupted boots.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Upgrade software.
Replace the Control Unit.
Restore the bus connection and set the con-
troller to RUN.
Check the physical bus configuration (ca-
ble, connector, Drive Bus terminator,
shielding, etc.).
Check whether communication was briefly
or permanently interrupted.
Check the bus and controller for utilization
level (e.g. bus cycle time was set too
short).