Sinamics V70 Parameters - Siemens SINUMERIK 808D ADVANCED Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

No.
Name
35140
GEAR_STEP_
MIN_VELO_LI
MIT[0] ... [5]
Minimum speed for gear stage
36100
POS_LIMIT_MI
NUS
1st software limit switch minus
Access level: Manufacturer
36110
POS_LIMIT_PL
US
1st software limit switch plus
36200
AX_VELO_LIMI
T[0] ... [5]
Threshold value for velocity monitoring
36300
ENC_FREQ_LI
MIT[0]
Encoder limit frequency
38000
MM_ENC_CO
MP_MAX_POI
NTS
Number of intermediate for interpolar compensation (SRAM)
The machine data followed by an asterisk (*) have the access level of "Customer", while those without an asterisk have the
access level of "Manufacturer".
16.2

SINAMICS V70 parameters

This section lists only the parameters displayed on the drive BOP and those frequently used for drive commissioning. For
more parameters of the servo drive, see SINUMERIK 808D ADVANCED HMI through the following operations:
+
All parameters beginning with "p" are editable parameters, for example, p29000.
All parameters beginning with "r" are read-only parameters, for example, r0018.
Effective
Indicates the conditions for making parameterization effective. Two conditions are possible:
● IM (Immediately): Parameter value becomes effective immediately after changing.
● RE (Reset): Parameter value becomes effective after repower-on.
Can be changed
Indicates the state in which a parameter is changeable. Two states are possible:
● U (Run): Can be changed in the "Running" state when the enable signal is available. The "RDY" LED indicator lights up
green.
● T (Ready to run): Can be changed in the "Ready" state when the enable signal is missing. The "RDY" LED indicator
lights up red.
Note
When judging the state of the drive according to the "RDY" LED indicator, ensure that no faults or alarms exist.
416
Default
Range
[0]...[1]: 5
-
[2]: 10
[3]: 20
[4]: 40
[5]: 80
-100,000,000
-
100,000,000
-
11,500
-
(mm/min)
31,944 (rpm)
3.33e5
-
Turning:
-
125
Milling: 200
Type
Unit
DOUBLE
rpm
DOUBLE
mm, degrees
DOUBLE
mm, degrees
DOUBLE
mm/min, rpm
DOUBLE
-
DWORD
-
Activating
CF
RE
RE
CF
PO
PO
Commissioning Manual